Good evening, I recently had a Buderus G installed with a Logamatic control that monitors the boiler and the DHW unit. I don’t. Manuals and User Guides for Buderus Logamatic We have 4 Buderus Logamatic manuals available for free PDF download: Applications Manual, . View and Download Buderus Logamatic applications manual online. Modular control system for floor standing boilers with indoor reset, outdoor reset, .

Author: Gugore Yoshura
Country: Oman
Language: English (Spanish)
Genre: Career
Published (Last): 16 April 2010
Pages: 481
PDF File Size: 13.36 Mb
ePub File Size: 17.28 Mb
ISBN: 647-2-58040-869-6
Downloads: 92789
Price: Free* [*Free Regsitration Required]
Uploader: Digrel

The thermostats are set higher than the heat reaches so the zone valves remain open, so the boiler is in essence heating the entire available load all the time. Buderus generally recommends the use of 3 way mixing valves when using a Buderus boiler. I moved into the house in and it was already installed so I do not know how old it is.

Nstallation Of The Logabracket Page 13 lofamatic 4 is the neutral. Unfortunately, you cannot down fire a Buderus oil boiler.

Buderus Logamatic 2107 Manuals

I’m attaching a filled-out version of the form. Terminal 64 and 63 go to L and N on the taco relay. It would make sense that it would be at least a little cooler though since it’s furthest out in the loop and the space under that is the unfinished portion that can get quite cold. As far as the dhw circ goes, it gets powered from 24 25 not the relay.

  DUA UKASHA PDF

It logajatic from the main AC input to the panel.

I am not sure why fig 9 only shows the one connection from 63 Hot going to ZC on the Taco. If you have a room sensor Logamatic Controls applications manual Avoid running wire parallel to telephone or line voltage wires. Consideration to boiler sizing must be given. The Log provides AC to the burner.

Buderus Logamatic Manuals

I hope this wasn’t too much in one post! Page 68 Buderus generally recommends the use of 3 way mixing valves when using a Logamatjc boiler. By pressing ‘print’ button you will print only current page. Maximum Boiler Temperature Unlike conventional setback thermostats that only reduce the zone temperature setting, the Buderus control system will operate the boiler at a reduced water temperature.

Bfu Remote Control When I install llgamatic I set it up like I explained.

What do you set your thermostat at? System Frost Protection Modifying Standard Programs The more specific, the better.

Same thing as the other one. Zoning compounds the problem because it throws fractional loads upon a boiler which is already over-sized for the total load of the entire house. Training and Education Pro’s Forum: The lowest temperature in this part of Connecticut can be anywhere from -2F rather extreme to 10F, based on logwmatic history in the past 10 years or so, so I figured 0F is a reasonable design temperature.

  ITEXT CONVERT WORDML PDF

Here are pics of bottom of Boilermate and the new sensor that goes to lotamatic Log.

New Install Wiring Help Needed – G115 / Logamatic 2107 / Taco SR504 / IDHW

Enter text from picture: The design temp for the area is on that form too. General Discussion Pro’s Forum: I don’t know if this applies to non contractors but the coil inside has a lifetime warranty. Find all posts by pickncrew. I guess in my mind I’m thinking there’s some sort of formula in which I plug in certain values for certain variables and end up with the right numbers for the Logamatic.

I’ve spoken to Taco engineers Logamatic Controls Applications Manual Figure 23 8. BB code is On.

Getting Pumped for ! If you go off the logo it over rides the reset for fast recovery. It’s nothing peculiar to the