MAMMOMAT 3000 NOVA PDF

Siemens – Mammomat NovaOutstanding versatility and excellent patient comfort, MAMMOMAT Nova is Siemen’s analog mammography system for. MedWrench Forums for Siemens Mammomat Nova, page 1. MAMMOMAT Nova clinical solutions are multi- purpose, reliable, and full of high-performance features. The system provides excellent return on investment.

Author: Voodoojind Sazuru
Country: Botswana
Language: English (Spanish)
Genre: Sex
Published (Last): 20 May 2008
Pages: 387
PDF File Size: 9.4 Mb
ePub File Size: 20.54 Mb
ISBN: 118-7-14468-342-8
Downloads: 22934
Price: Free* [*Free Regsitration Required]
Uploader: Nikotaur

This is not as simple as it sounds, though, as a very high-quality, high-resolution detector must replace the object table film-holder, where the breast is positionedthe image must be transferred quickly and in full resolution to the monitor, and the detector must be mammomqt within seconds to acquire the next image.

The object table always remains at the same height, making repositioning almost unnecessary. You can add Community Subscriptions in the search bar that says “Subscribe to more communities Similar Equipment For Sale. Thus, it is less likely that too little compression is used – producing inferior images – or too much compression is used, making the patient uncomfortable and anxious without improving image quality.

I have error in a Mammomat Nova. Optimized compression for highest image quality and patient comfort.

Siemens and 4Way Medicals Mammomat 3000 Nova Digital Mammography

The Mamkomat Health Resource. As mammography is used for both screening and diagnostic procedures, it is essential that dose exposure be kept as low as possible.

Use of this online service is subject to the disclaimer and the terms and conditions contained herein. With Siemens’ proven Mammography technology, the medical community is equipped to successfully address the increasing challenges resulting from today’s disease incidence and changing economic circumstances.

Want to make a correction? The attractive, patient-friendly and comfortable design allows the patient to sit, stand or lie down during the examination. I need the service manual to installation and calibration of the machine. Pivoting bucky The pivoting bucky table enables quick and easy switching between 18 cm x 24 cm and 24 cm x 30 cm formats. The left frame of this figure shows the breast during compression.

  FINACLE MENU OPTIONS PDF

When the object table is changed, the appropriate collimation is automatically preselected.

All other trademarks and copyrights are property of their 3000 owners. Information found within the Imaginis. Siemens is currently investing significant resources into Full Field Digital Mammography development, and has the first prototype installed and in clinical use.

Siemens – MAMMOMAT 3000 Nova / 1000 – saving lives by early detection of breast cancer

Advertise Increase Your Brand Niva. Thanks in advancemy e-mail: Then when tried to start the system a boom sounds and again the V1-V4 transistors blown. My Bench Order History Sign out. Mammomat Nova error The resulting images are of convincing quality and retakes are reduced to a minimum.

Used SIEMENS Mammomat Nova Mammo Unit For Sale – DOTmed Listing #

It happens during obligue tube positioning and you can not give the exposure! Display in Community Feed. Seek immediate medical attention if your condition is urgent. Siemens mammomat nova. With Opcomp, the compression is increased as long as the nov is soft and pliable – then it stops. The ability to integrate with a variety of CR readers makes it easy to upgrade to digital.

We think it may have something to do with the grid motors on the small bucky, but we want to be sure. Only your Nickname and photo, if you use one will identify you — no personal or company information will appear. Siemens – Mammomat Nova. The superb system design also allows easy access for the physician to perform stereotactic biopsy procedures.

  DENMANS CONNECTOR PDF

As the breast becomes compressed, the orange line shows increasing image quality and the green line shows increasing patient discomfort. Read about how Siemens has made mammography more comfortable for patients requires Adobe Acrobat Reader. An optionally available perforated biopsy compression plate and magnification tables further mamjomat the scope of applications.

Mammographic screening and diagnostic technologies are now available to more women than ever before, enabling physicians to detect suspected cancers at their earliest, most treatable stages.

Remove Subscription Confirm Remove. When women complained about uncomfortable traditional mammography, Siemens listened. One system for all applications Clear results User-friendly operation.

Forums Documents Parts Videos News. Compression plates A wide array of compression plates ensures gentle compression optimized for each individual breast. The content may recently have been changed or altered by someone whose opinion does not correspond with nlva state of knowledge in the relevant fields. Please mammoamt Thanks, Xavier Altamirano xavieralt hotmail.

The blue line on the graph shows decreasing breast thickness as compression is applied. Digital Mammo Unit Models. Print Discuss Email Share. Please review our Privacy Policy for more details. This is especially important in screening programs for younger women, as their breasts normally have higher density, typically requiring higher dose. See a missing Specification?

Sign In or Register. Your Nickname can only contain letters, numbers, dashes, underscores and periods.